High pressure superheated steam flow | ~480 | t/h |
High pressure superheated steam outlet pressure | ~17.3 | MPa(g) |
High pressure superheated steam outlet temperature | 602 | ℃ |
Reheated steam flow | ~524 | t/h |
Reheated steam outlet pressure | 602 | ℃ |
Feed water temperature | ~36 | ℃ |
Application of H Class Combined Cycle units of large capacity and high parameter is still at an initial stage in China. However, SBWL had started the development of HRSG matched with H class since 2013, and undertook the first order of HRSG matched with H class in 2017, being one of the first participants in the market.
The boiler has low barycenter, strong shock resistance, long service life of heating surface, reasonable arrangement of inlet gas duct, uniform airflow field, tube bundle location and antivibration baffle which can effectively eliminate vibration and prevent noise. It has advantage of easy field installation and short construction time.
- Shanghai Boiler Works Co Ltd.