Shanghai Electric-KSB Nuclear Pumps Valves Co.,Ltd.-_正规赌钱软件app
RSR
Applications: Reactor coolant recirculation in nuclear power stations (PWR)

    Changjiang 1, taking Qinshan 2 as reference, is equipped with two 650 MW pressurized water reactors. SEC-KSB provided 4 RSRs and shall perform all the maintenance service work for Changjiang1.

With advanced technology and reliable performance, the RSRs have entered the TOP 3 List of Chinese reactor coolant pumps installed.

? 100% tightness 100%

l Improved 3 mechanical seals (double-redundant) plus 2 standstill seals to withstand the SBO condition

? Integrity under upset conditions

l Cooling of mechanical seals through thermosyphon effect

l Newly-developed Passive Thermal Control Valve to ensure integrity of primary loop through closing control leakage line in several minutes without any supply of power or nitrogen under SBO condition

? Operational safety

l Medium-lubricated guide bearing

? Perfect rotor alignment

l Through Hirth-type serration of connections

? Optimized hydraulics

l Tailor-made impeller/diffuser combination

l Model and full-load performance tests

Contact Us
Shanghai Electric-KSB Nuclear Pumps & Valves Co., Ltd.
Address:No.257 Yitian Rd., Pudong District, Shanghai, China
Post code:201306
Tel: +86 21 38221500
Fax:+86 21 38221501